T60 UV-Vis Spectrophotometer
Compact Split-Beam Spectrophotometer with 2 nm Fixed Bandwidth
The T60 Series by PG Instruments is a reliable, high-performance range of compact split-beam spectrophotometers, available in two versions:
-
T60U (UV-Visible) – 190 to 1100 nm wavelength range
-
T60V (Visible) – 325 to 1100 nm wavelength range
Designed with advanced optical components and a robust modular structure, the T60 delivers high-quality analytical performance at an affordable price. Its compact footprint makes it ideal for laboratories with limited space, while its precision and versatility support both routine and research-grade applications.
🔍 Key Features
-
Fixed 2 nm spectral bandwidth for consistent resolution
-
Low stray light: ≤ 0.05%T (T60U), ≤ 1.0%T (T60V)
-
Wavelength accuracy: ±1 nm (T60U), ±2 nm (T60V)
-
Advanced holographic blazed grating (1200 lines/mm)
-
Photometric modes: Transmittance, Absorbance, Energy, Concentration
-
Local control via built-in software and optional UV-Win PC software
-
Mini printer included for quick data output
-
Built-in cell holder storage and optional 5 or 8-cell changers
-
Long-life deuterium and tungsten-halogen lamps with self-timers
-
Environmentally friendly, corrosion-resistant housing
🧪 Typical Applications
-
General purpose absorbance and transmittance analysis
-
Water and wastewater testing
-
Quantitative determination of ions and compounds in chemical, pharmaceutical and food labs
-
Education and research in academic environments
-
Kinetics and multi-wavelength spectrum measurements (with upgrades)
📊 Technical Specifications – T60U & T60V
Specification |
T60U (UV-Vis) |
T60V (Visible) |
---|---|---|
Optical System | Split beam | Split beam |
Wavelength Range | 190 – 1100 nm | 325 – 1100 nm |
Wavelength Accuracy | ±1 nm | ±2 nm |
Wavelength Reproducibility | ≤ 0.2 nm | ≤ 0.4 nm |
Spectral Bandwidth | 2 nm | 2 nm |
Photometric Modes | T, A, E, C | T, A, E, C |
Photometric Range | -0.3 to 3.0 Abs | -0.3 to 3.0 Abs |
Photometric Accuracy | 0.002A (0–0.5A), 0.004A (0.5–1A) | 0.002A (0–0.5A), 0.004A (0.5–1A) |
Photometric Reproducibility | 0.001A (0–0.5A), 0.002A (0.5–1A) | 0.001A (0–0.5A), 0.002A (0.5–1A) |
Baseline Flatness | 0.002A (200–1000 nm) | 0.002A (325–1000 nm) |
Baseline Stability | 0.001A/h (500 nm, 0 Abs, 2 h warm-up) | 0.002A/h (500 nm, 0 Abs, 2 h warm-up) |
Stray Light | ≤ 0.05%T (220 nm NaI) | ≤ 1.0%T (340 nm NaNO₂) |
Detector | Silicon photodiode | Silicon photodiode |
Light Source | Tungsten Halogen & Deuterium Arc | Tungsten Halogen |
Display | Digital LCD | Digital LCD |
Printer | Mini thermal printer (built-in) | Mini thermal printer (built-in) |
Software Support | Local & UV-Win (optional) | Local & UV-Win (optional) |
Power Supply | 95–250V AC, 50–60Hz (switch mode) | 95–250V AC, 50–60Hz (switch mode) |
Interface | RS232 | RS232 |
Dimensions (W×D×H) | 476 × 362 × 225 mm | 476 × 362 × 225 mm |
Weight | 11 kg | 11 kg |
👉 For more information, click here.
T65 UV-Vis Spectrophotometer
Advanced Single-Beam Spectrophotometer with Variable Bandwidth and Touchscreen Control
The T65 Series is a powerful and versatile line of single-beam UV-Visible spectrophotometers from PG Instruments, offering robust photometric performance for a wide range of analytical applications. With both fixed (1.8 nm) and variable bandwidth options (1, 2, 4, 5 nm), a 7-inch capacitive touchscreen, and full software compatibility, the T65 delivers flexibility, ease of use, and analytical precision.
Designed for research, education, QC, and GLP/GMP environments, the T65 enables standalone operation or PC-based control via SPA-Win software, ensuring compliance with 21 CFR Part 11.
🔍 Key Features
-
High-performance single-beam optical system
-
Variable or fixed spectral bandwidth (1.8 nm / 1, 2, 4, 5 nm)
-
7-inch touch screen with fast response and intuitive UI
-
Pre-aligned tungsten and deuterium lamps for stability across the full wavelength range
-
Motorised 8-position cell changer included as standard
-
Standalone analysis modes: Photometric, Quantitative, Kinetic, Multi-wavelength, Spectrum scanning, DNA/Protein
-
Easy-access modular design for maintenance and optical cleaning
-
SPA-Win software with GLP/GMP support, audit trail, and user account control
-
Compatible with external printers and USB data export
🧪 Typical Applications
-
Quantitative analysis in chemical, environmental, and pharmaceutical labs
-
Kinetics, DNA/Protein concentration, and multi-wavelength testing
-
Spectral scanning of unknown compounds
-
Educational use in teaching UV-Vis principles
-
Method validation and documentation in regulated environments
📊 Technical Specifications – T65 Series
Specification |
T65V |
T65UV |
T65UV+ |
---|---|---|---|
Optical System | Single Beam | Single Beam | Single Beam |
Wavelength Range | 325 – 1100 nm | 190 – 1100 nm | 190 – 1100 nm |
Spectral Bandwidth | Fixed 1.8 nm | Variable 1, 2, 4, 5 nm | Variable 1, 2, 4, 5 nm |
Wavelength Accuracy | ± 0.5 nm | ± 0.5 nm | ± 0.5 nm |
Wavelength Reproducibility | ≤ 0.2 nm | ≤ 0.2 nm | ≤ 0.2 nm |
Photometric Modes | T, A, E, C | T, A, E, C | T, A, E, C |
Photometric Range | -0.3 to 3.0 Abs | -0.3 to 3.0 Abs | -0.3 to 3.0 Abs |
Photometric Accuracy | 0.002A (0–0.5A), 0.004A (0.5–1A) | 0.002A (0–0.5A), 0.004A (0.5–1A) | 0.002A (0–0.5A), 0.004A (0.5–1A) |
Photometric Reproducibility | 0.001A (0–0.5A), 0.002A (0.5–1A) | 0.001A (0–0.5A), 0.002A (0.5–1A) | 0.001A (0–0.5A), 0.002A (0.5–1A) |
Photometric Noise | 0.001A @ 500 nm (30 min warm-up) | 0.001A @ 500 nm (30 min warm-up) | 0.001A @ 500 nm (30 min warm-up) |
Baseline Flatness | 0.002A | 0.002A | 0.002A |
Baseline Stability | 0.001A/h (500 nm, 0Abs) | 0.001A/h (500 nm, 0Abs) | 0.001A/h (500 nm, 0Abs) |
Stray Light | ≤ 0.05%T | ≤ 0.05%T | ≤ 0.05%T |
Cell Holder | Motorised 8-cell changer | Motorised 8-cell changer | Motorised 8-cell changer |
Detector | Silicon Photodiode | Silicon Photodiode | Silicon Photodiode |
Display | 7-inch 800×480 Touchscreen | 7-inch 800×480 Touchscreen | 7-inch 800×480 Touchscreen |
Interface | USB | USB | USB |
Software Support | Local & SPA-Win | Local & SPA-Win | Local & SPA-Win |
Light Source | Tungsten | Tungsten + Deuterium | Tungsten + Deuterium |
Power Supply | 230VAC 50Hz / 120VAC 60Hz | 230VAC 50Hz / 120VAC 60Hz | 230VAC 50Hz / 120VAC 60Hz |
Printer Support | External inkjet or laser | External inkjet or laser | External inkjet or laser |
Dimensions (W×D×H) | 490 × 370 × 210 mm | 490 × 370 × 210 mm | 490 × 370 × 210 mm |
Weight | 20 kg | 20 kg | 20 kg |
👉 For more information, click here.
T70 / T70+ UV-Vis Spectrophotometers
High-Performance Split-Beam Spectrophotometers with Fixed or Variable Bandwidth
The T70 Series from PG Instruments offers precise and reliable UV-Visible spectrophotometry in a modern, compact design. With split-beam optical configuration, the T70 ensures excellent photometric stability and reduced noise, making it ideal for both research and routine laboratory use.
The range includes two models:
-
T70: with a fixed 2 nm spectral bandwidth
-
T70+: with variable bandwidth selection (0.5, 1, 2, or 5 nm)
Both instruments support a wide range of applications, including photometric analysis, quantification, spectrum scans, and DNA/protein measurement. With UV-Win software integration, users gain access to extended functionality such as 3D spectral views, kinetic studies, and GLP-compliant features.
🔍 Key Features
-
Split-beam optical system for high optical stability
-
Choice of fixed (2 nm) or variable (0.5–5 nm) bandwidth
-
Wavelength accuracy ±0.3 nm, reproducibility ≤0.2 nm
-
Supplied with motorised 8-position cell changer
-
Pre-aligned deuterium and tungsten lamps for stability and easy replacement
-
Supports photometric, quantitative, spectrum, and DNA/protein analysis
-
Full compatibility with UV-Win software for data storage, export, GLP protocol, and audit trails
-
Compact, modular mechanical design for easy maintenance
-
RS232 and USB interface for PC connectivity
-
Ideal for research, education, clinical, pharmaceutical, and environmental labs
🧪 Typical Applications
-
Quantitative and qualitative analysis of compounds in solution
-
DNA and protein concentration determination
-
Spectral scanning and peak analysis
-
Educational demonstration and academic research
-
Analytical method development and validation
📊 Technical Specifications – T70 Series
Specification |
T70 |
T70+ |
---|---|---|
Optical System | Split beam | Split beam |
Wavelength Range | 190 – 1100 nm | 190 – 1100 nm |
Spectral Bandwidth | Fixed 2 nm | Variable 0.5, 1, 2, 5 nm |
Wavelength Accuracy | ± 0.3 nm | ± 0.3 nm |
Wavelength Reproducibility | ≤ 0.2 nm | ≤ 0.2 nm |
Photometric Modes | T, A, E, C | T, A, E, C |
Photometric Range | -0.3 to 3.0 Abs | -0.3 to 3.0 Abs |
Photometric Accuracy | 0.002A (0–0.5A), 0.004A (0.5–1A) | 0.002A (0–0.5A), 0.004A (0.5–1A) |
Photometric Reproducibility | 0.001A (0–0.5A), 0.002A (0.5–1A) | 0.001A (0–0.5A), 0.002A (0.5–1A) |
Photometric Noise | 0.001A @ 500 nm (30 min warm-up) | 0.001A @ 500 nm (30 min warm-up) |
Baseline Flatness | 0.002A (200–1000 nm) | 0.002A (200–1000 nm) |
Baseline Stability | 0.001A/h @ 500 nm (2 hr warm-up) | 0.001A/h @ 500 nm (2 hr warm-up) |
Stray Light | ≤ 0.12%T (220 nm NaI, 340 nm NaNO₂) | ≤ 0.12%T (220 nm NaI, 340 nm NaNO₂) |
Standard Functions | Photometric, Quantitative, Spectrum, DNA/Protein | Photometric, Quantitative, Spectrum, DNA/Protein |
Cell Holder | Motorised 8-position | Motorised 8-position |
Detector | Silicon photodiode | Silicon photodiode |
Light Source | Tungsten + Deuterium arc lamps | Tungsten + Deuterium arc lamps |
Display | Digital LCD | Digital LCD |
Printer | Not available | Not available |
PC Interface | RS232 / USB | RS232 / USB |
Software | Local control & UV-Win | Local control & UV-Win |
Power Supply | 120–230 VAC, 50–60 Hz (switchable) | 120–230 VAC, 50–60 Hz (switchable) |
Dimensions (W×D×H) | 520 × 420 × 230 mm | 520 × 420 × 230 mm |
Weight | 25 kg | 25 kg |
👉 For more information, click here.
T75 / T75+ UV-Vis Spectrophotometers
High-Performance Dual Beam Instruments with Fixed or Variable Bandwidth & Integrated Touchscreen
The PG Instruments T75 Series represents a modern generation of dual-beam UV-Vis spectrophotometers, combining optical precision, high functionality, and ease of use. The system features an embedded PC with a Windows 8 touchscreen interface, pre-installed with the latest UV-Win 6 software, supporting a wide range of analysis functions and GLP/GMP compliance.
Two models are available:
-
T75: fixed 2 nm spectral bandwidth
-
T75+: variable bandwidth (0.5, 1.0, 2.0, 5.0 nm)
Designed for versatility in research, industrial QC, and academic environments, the T75 Series offers high-resolution performance, intuitive operation, and easy maintenance — all in a compact, robust design.
🔍 Key Features
-
Dual-beam optical system for high stability and precision
-
Fixed or variable bandwidth options to suit application needs
-
Wavelength accuracy ±0.3 nm, reproducibility ≤0.2 nm
-
Pre-aligned tungsten and deuterium lamps with long life and easy replacement
-
Built-in motorised 8-position cell changer
-
Large sample compartment and cuvette storage for 8×10 cm cells
-
Touchscreen control with Windows 8 OS
-
UV-Win 6 software preloaded, supporting photometric, quantitative, spectrum, kinetic, and 3D analysis
-
GLP functionality: audit trail, secure user management, method/data storage
-
Simple modular design for low-maintenance operation
-
USB printer and data export capability
🧪 Typical Applications
-
Photometric and quantitative analysis of compounds in solution
-
Spectrum scanning and 3D visualisation of samples
-
Protein and DNA quantification
-
Kinetics and reaction monitoring
-
Suitable for pharmaceutical, food, environmental, chemical, and academic laboratories
📊 Technical Specifications – T75 Series
Specification |
T75 |
T75+ |
---|---|---|
Optical System | Dual beam | Dual beam |
Scan Speed | Selectable | Selectable |
Wavelength Range | 190 – 1100 nm | 190 – 1100 nm |
Wavelength Accuracy | ± 0.3 nm | ± 0.3 nm |
Wavelength Reproducibility | ≤ 0.2 nm | ≤ 0.2 nm |
Spectral Bandwidth | Fixed 2 nm | Variable 0.5, 1.0, 2.0, 5.0 nm |
Photometric Modes | Transmittance, Absorbance, Energy, Concentration | Transmittance, Absorbance, Energy, Concentration |
Photometric Range | -0.3 to 3.0 Abs | -0.3 to 3.0 Abs |
Photometric Accuracy | 0.002A (0–0.5A), 0.004A (0.5–1.0A), 0.3%T | 0.002A (0–0.5A), 0.004A (0.5–1.0A), 0.3%T |
Photometric Noise | 0.001A (500 nm, 30 min warm-up) | 0.001A (500 nm, 30 min warm-up) |
Baseline Flatness | 0.0015A (200–1000 nm) | 0.0015A (200–1000 nm) |
Baseline Stability | 0.0008A/h (500 nm, 2 hr warm-up) | 0.0008A/h (500 nm, 2 hr warm-up) |
Stray Light | < 0.05%T (220 nm NaI) – pharmacopeia compliant | < 0.05%T (220 nm NaI) – pharmacopeia compliant |
Standard Functions | Photometric, Quantitative, Spectrum, Kinetic | Photometric, Quantitative, Spectrum, Kinetic |
Cell Holder | Motorised 8-position cell changer | Motorised 8-position cell changer |
Detector | Silicon photodiode | Silicon photodiode |
Light Source | Tungsten Halogen & Deuterium Arc Lamps | Same as T75 |
Instrument Control | Embedded PC touchscreen (Windows 8) | Same as T75 |
Printer Support | Any USB printer | Any USB printer |
Software | UV-Win 6 | UV-Win 6 |
Power Supply | 120–230 VAC, 50–60 Hz (switchable) | 120–230 VAC, 50–60 Hz (switchable) |
Dimensions (W×D×H) | 520 × 420 × 230 mm | 520 × 420 × 230 mm |
Weight | 25 kg | 25 kg |
👉 For more information, click here.
T80 / T80+ UV-Vis Spectrophotometers
Dual-Beam Instruments with Fixed or Variable Bandwidth and UV-Win Software Compatibility
The T80 Series from PG Instruments represents a high-performance generation of dual-beam UV-Vis spectrophotometers, available with either a fixed spectral bandwidth of 2 nm or variable bandwidth (0.5, 1.0, 2.0, 5.0 nm). With a modular mechanical and optical design, the T80 offers stability, reliability, and ease of maintenance.
These instruments are suitable for photometric analysis, spectrum scanning, quantitative measurement, and DNA/protein analysis, and when paired with UV-Win software, they unlock a wide array of advanced features including 3D spectral analysis, kinetic measurements, data export, and GLP compliance.
🔍 Key Features
-
Dual-beam optics for superior analytical stability
-
Fixed (T80) or variable (T80+) spectral bandwidth options
-
Wavelength accuracy ±0.3 nm, reproducibility ≤0.2 nm
-
Motorised 8-cell changer included as standard
-
High-quality pre-aligned tungsten and deuterium lamps
-
Holographic blazed grating with 1200 lines/mm
-
Low stray light and photometric noise
-
Modular structure for easy cleaning and maintenance
-
UV-Win software compatibility for full PC control, 3D scans, GLP audit trail, and method storage
-
Simple keypad operation with minimal setup steps
🧪 Typical Applications
-
Routine and advanced photometric measurements
-
Quantification of analytes in chemical, environmental, or pharmaceutical labs
-
DNA and protein concentration measurement
-
Method development and validation
-
Teaching and academic use in analytical chemistry
📊 Technical Specifications – T80 Series
Specification |
T80 |
T80+ |
---|---|---|
Optical System | Dual beam | Dual beam |
Scan Speed | Selectable | Selectable |
Wavelength Range | 190 – 1100 nm | 190 – 1100 nm |
Wavelength Accuracy | ± 0.3 nm | ± 0.3 nm |
Wavelength Reproducibility | ≤ 0.2 nm | ≤ 0.2 nm |
Spectral Bandwidth | Fixed 2.0 nm | Variable: 0.5, 1.0, 2.0, 5.0 nm |
Photometric Modes | Transmittance, Absorbance, Energy, Concentration | Transmittance, Absorbance, Energy, Concentration |
Photometric Range | -0.3 to 3.0 Abs | -0.3 to 3.0 Abs |
Photometric Accuracy | 0.002A (0–0.5A), 0.004A (0.5–1.0A), 0.3%T | 0.002A (0–0.5A), 0.004A (0.5–1.0A), 0.3%T |
Photometric Reproducibility | 0.001A (0–0.5A), 0.002A (0.5–1.0A), 0.15%T | 0.001A (0–0.5A), 0.002A (0.5–1.0A), 0.15%T |
Photometric Noise | 0.001A @ 500 nm (30 min warm-up) | 0.001A @ 500 nm (30 min warm-up) |
Baseline Flatness | 0.0015A (200–1000 nm) | 0.0015A (200–1000 nm) |
Baseline Stability | 0.0008A/h @ 500 nm (2 hr warm-up) | 0.0008A/h @ 500 nm (2 hr warm-up) |
Stray Light | ≤ 0.12%T (220 nm NaI, 340 nm NaNO₂) | ≤ 0.12%T (220 nm NaI, 340 nm NaNO₂) |
Standard Functions | Photometric, Quantitative, Spectrum, DNA | Photometric, Quantitative, Spectrum, DNA |
Cell Holder | Motorised 8-position cell changer | Motorised 8-position cell changer |
Detector | Silicon photodiode | Silicon photodiode |
Light Source | Tungsten Halogen & Deuterium arc lamps | Tungsten Halogen & Deuterium arc lamps |
Display | Digital LCD display | Digital LCD display |
Printer | Not available | Not available |
PC Interface | RS232 / USB | RS232 / USB |
Software Support | Local & UV-Win | Local & UV-Win |
Power Supply | 120–230 VAC, 50–60 Hz (switchable) | 120–230 VAC, 50–60 Hz (switchable) |
Dimensions (W×D×H) | 520 × 420 × 230 mm | 520 × 420 × 230 mm |
Weight | 25 kg | 25 kg |
👉 For more information, click here.
T85 / T85+ UV-Vis Spectrophotometers
Dual-Beam Systems with Fixed or Variable Bandwidth and High Photometric Accuracy
The PG Instruments T85 Series offers advanced dual-beam UV-Visible spectrophotometers, engineered for analytical accuracy, robust operation, and flexibility in various laboratory environments. The instruments are designed for routine use in industries such as pharmaceuticals, food and beverage, environmental analysis, and academic research.
The range includes:
-
T85: Dual-beam spectrophotometer with a fixed 1.8 nm bandwidth
-
T85+: Enhanced model with variable bandwidth (0.5, 1.0, 2.0, 4.0 nm) for demanding applications
With low stray light, high baseline stability, and modular mechanics, the T85 series delivers outstanding performance, particularly in quantitative analysis, spectrum scanning, and multi-component analysis.
🔍 Key Features
-
Dual-beam optical system for accurate and stable measurements
-
Fixed (1.8 nm) or variable (0.5–4.0 nm) spectral bandwidth
-
Wavelength accuracy ±0.3 nm, reproducibility ≤0.2 nm
-
Excellent photometric precision and low noise
-
Full support for photometric, quantitative, spectrum, kinetics, and DNA/protein analysis
-
Modular optical/mechanical design for easy servicing and lamp replacement
-
Supplied with motorised 8-cell changer as standard
-
Compatible with UV-Win software for PC control, method saving, audit trails, and GLP compliance
-
Ideal for advanced quality control, research, and academic teaching labs
🧪 Typical Applications
-
Quantification of active ingredients or ions in solution
-
DNA and protein concentration analysis
-
Spectrum scanning and peak detection
-
Multi-component analysis for industrial or pharmaceutical samples
-
Educational experiments involving UV-Vis principles
📊 Technical Specifications – T85 Series
Specification |
T85 |
T85+ |
---|---|---|
Optical System | Dual beam | Dual beam |
Wavelength Range | 190 – 1100 nm | 190 – 1100 nm |
Wavelength Accuracy | ± 0.3 nm | ± 0.3 nm |
Wavelength Reproducibility | ≤ 0.2 nm | ≤ 0.2 nm |
Spectral Bandwidth | Fixed 1.8 nm | Variable: 0.5, 1.0, 2.0, 4.0 nm |
Photometric Modes | Transmittance, Absorbance, Energy, Concentration | Transmittance, Absorbance, Energy, Concentration |
Photometric Range | -0.3 to 3.0 Abs | -0.3 to 3.0 Abs |
Photometric Accuracy | ±0.002A (0–0.5A), ±0.004A (0.5–1A), ±0.3%T | ±0.002A (0–0.5A), ±0.004A (0.5–1A), ±0.3%T |
Photometric Reproducibility | ±0.001A (0–0.5A), ±0.002A (0.5–1A), ±0.15%T | ±0.001A (0–0.5A), ±0.002A (0.5–1A), ±0.15%T |
Photometric Noise | ≤ 0.001A @ 500 nm (after 30 min warm-up) | ≤ 0.001A @ 500 nm (after 30 min warm-up) |
Baseline Flatness | 0.0015A (200–1000 nm) | 0.0015A (200–1000 nm) |
Baseline Stability | 0.0008A/h @ 500 nm (after 2 h warm-up) | 0.0008A/h @ 500 nm (after 2 h warm-up) |
Stray Light | ≤ 0.12%T (220 nm NaI, 340 nm NaNO₂) | ≤ 0.12%T (220 nm NaI, 340 nm NaNO₂) |
Standard Functions | Photometric, Quantitative, Spectrum, Kinetics, DNA/Protein | Photometric, Quantitative, Spectrum, Kinetics, DNA/Protein |
Cell Holder | Motorised 8-position cell changer | Motorised 8-position cell changer |
Detector | Silicon photodiode | Silicon photodiode |
Light Source | Tungsten Halogen & Deuterium arc lamps | Tungsten Halogen & Deuterium arc lamps |
Display | Digital LCD display | Digital LCD display |
PC Interface | RS232 / USB | RS232 / USB |
Software Support | Local & UV-Win | Local & UV-Win |
Power Supply | 120–230 VAC, 50–60 Hz | 120–230 VAC, 50–60 Hz |
Dimensions (W×D×H) | 520 × 420 × 230 mm | 520 × 420 × 230 mm |
Weight | 25 kg | 25 kg |
👉 For more information, click here.
T110+ / T112+ UV-Vis Spectrophotometers
Advanced Dual-Monochromator Systems for High-End UV-Visible Spectroscopy
The T110+ and T112+ spectrophotometers by PG Instruments are high-end systems designed for the most demanding applications in UV-Visible spectroscopy, including pharmaceutical analysis, material science, biotechnology, metrological verification, and research.
Both instruments are equipped with a dual-monochromator, double-beam optical system, allowing for exceptional stray light suppression, superior wavelength accuracy, and a wide photometric range. Their optics and mechanics are designed to support variable spectral resolution, offering users maximum flexibility for a range of sample types and methods.
Built with modern connectivity options, these instruments support RS232, USB, and wireless (Wi-Fi) control, enabling remote operation via tablet PC. Advanced accessories such as integrating spheres, polarizing optics, temperature-controlled cell holders, and tablet dissolution modules are available to expand system capabilities.
🔍 Key Features
-
Dual monochromator double-beam system with ultra-low stray light (as low as 0.00002%T)
-
Continually adjustable spectral bandwidth from 0.1 to 50.0 nm
-
Wavelength accuracy of ±0.2 nm, reproducibility ≤0.1 nm
-
Wide photometric range: up to ±8.0 Abs
-
Integrated Mercury Emissions Lamp for automatic wavelength correction
-
Wi-Fi connectivity for remote monitoring and control via tablet PC
-
Modular accessory support for integrating spheres, polarizers, temperature control, and automated cell changers
-
Ideal for pharmaceutical QC, material testing, environmental analysis, and advanced academic research
🧪 Typical Applications
-
Measurement of highly absorbent or dilute samples with extreme precision
-
Deep UV analysis using nitrogen-purged optics
-
Diffuse and specular reflectance using integrating spheres
-
High-accuracy analysis in pharmaceutical and regulatory environments
-
Advanced kinetic studies and multi-component assays
📊 Technical Specifications – T110+ / T112+
Specification |
T110+ |
T112+ |
---|---|---|
Optical System | Dual Monochromator, Double Beam | Dual Monochromator, Double Beam |
Wavelength Range | 185 – 900 nm | 185 – 900 nm |
Wavelength Accuracy | ± 0.2 nm | ± 0.2 nm |
Wavelength Reproducibility | ≤ 0.1 nm (D2 lamp) | ≤ 0.1 nm (D2 lamp) |
Spectral Bandwidth | 0.1 – 50.0 nm (continuously adjustable) | 0.1 – 50.0 nm (continuously adjustable) |
Stray Light | ≤ 0.00004%T (NaI 220 nm) | ≤ 0.00002%T (NaNO₃ 360 nm) |
Photometric Range | -6.0 to +6.0 Abs | -8.0 to +8.0 Abs |
Photometric Accuracy | ±0.004A @ 2.0A | ±0.004A @ 2.0A |
±0.003A @ 1.0A | ±0.003A @ 1.0A | |
±0.002A @ 0.5A | ±0.002A @ 0.5A | |
±0.3% | ±0.3% | |
Photometric Reproducibility | ≤ 0.002A @ 2.0A | ≤ 0.002A @ 2.0A |
≤ 0.0008A @ 1.0A | ≤ 0.0008A @ 1.0A | |
≤ 0.0004A @ 0.5A | ≤ 0.0004A @ 0.5A | |
≤ 0.1% | ≤ 0.1% | |
Baseline Flatness | ± 0.0008 Abs | ± 0.0005 Abs |
Noise | 0% Noise: ≤ 0.01% | 0% Noise: ≤ 0.01% |
100%T Noise: ≤ 0.1% | 100%T Noise: ≤ 0.1% | |
Light Source | Deuterium (UV), Tungsten (Visible) | Deuterium (UV), Tungsten (Visible) |
Wavelength Correction | Mercury Emission Lamp (built-in) | Mercury Emission Lamp (built-in) |
Connectivity | RS232C, USB, Wi-Fi | RS232C, USB, Wi-Fi |
👉 For more information, click here.